What are the Common Faults of The Mixing Plant?
As an Asphalt Mixing Plant Manufacturer , share with you. Air source failure (1) Air compressor failures include: check valve damage, severe wear of the piston ring, damage to the intake valve and blockage of the air filter, etc. If you want to judge whether the check valve is damaged, you only need to turn off the power after the air compressor stops automatically for more than ten seconds, and turn the big belt wheel with your hand. If it can turn around easily, it means that the check valve is not damaged. ; On the contrary, the check valve is damaged; in addition, it can also be judged from the exhaust situation of the exhaust port under the automatic pressure switch. Generally, the exhaust should be stopped after about ten seconds after the air compressor is automatically shut down. If it is exhausting until the air compressor starts again, it means that the check valve is damaged and must be replaced. Asphalt Mixing Plant When the pressure of the air compressor rises slowly...